Hytrol Slider Bed Belt Conveyors & Roller Bed Conveyors

Hytrol EZ-Logic Components and Accessories

Hytrol EZ-Logic Components and Conveyor Accessories are listed in categories, “Conveyor Accessories”, “System Accessories” and “EZ-Logic Components”. This page lists Hytrol EZ-Logic Components.
To see other Hytrol Accessories click Click on an image for more information….

Conveyor Accessories
.

Conveyor Accessories

Conveyor System Accessories

 

Hytrol Conveyor System Accessories

Hytrol EZ-Logic Components

   See Below …
Hytrol EZ-Logic Components

 

 

Hytrol EZ-Logic Components:

Hytrol has created the most advanced zero-pressure accumulation system in the world. While featuring the same EZLogic® familiarity. GEN3 incorporates new technologies for ease of installation, operation, and maintenance.

The EZ-Logic components are used on the following conveyors: 138-NSPEZ, 190-NSPEZ, 190-NSPEZC, ABEZ, 190-PREZ, 190-PREZC, 25-LREZ, 199-CREZD, 25-CREZD, 36-CREZD, CCEZ, DCEZ-60, DCEZ-63, DCEZ-82, DCEZ-83, and PLEZD.

Download Complete Documentation:
Download  Hytrol EZ-Logic Components
Download EZ-Logic Component Manual  Hytrol EZ-Logic Component Manual

Hytrol EZ-Logic ComponentsZONE CCONTROLLERS QUICK REFERENCE:

Retro-Reflective Type Zone Controller
Zone controller including mounting base and unitized retro-reflective transducer.
Part Number: 032.501

Diffuse Type Zone Controller
Zone controller including mounting base and unitized diffuse transducer with adjustable sensitivity (through programming).
Part Number: 032.502

Enhanced Retro-Reflective Zone Controller
Same as standard, plus used for IOP communication, and addressable remote access.
Part Number: 032.505

Enhanced Diffuse Zone Controller
Same as standard, plus used for IOP communication, and addressable remote access.
Part Number: 032.506

Remote Zone Controller
Zone controller including mounting base. Connectorized for attaching any remote transducer.
Part Number: 032.504

Enhanced Zone Controller
Enhanced zone controller including mounting base. Connectorized for attaching any remote transducer. Same as standard, plus used for IOP communication, and addressable remote access.
Part Number: 032.507

 

Transducers SensorTRANSDUCERS (SENSORS) QUICK REFERENCE:

Remote Diffuse Transducer (Narrow Beam)
Has narrow beam for use with close roller centers. Attaches to any remote zone controller and allows transducer to be mounted separate from controller.
Part Number: 032.513

 

Hytrol EZ-Logic Controller CordsetCORDSETS QUICK REFERENCE:

Zone Controller Cordset (Zone to Zone Communication)
Available for the following zone lengths:

  • 12”…………………………………………………. Part Number: 032.551
  • 18”…………………………………………………. Part Number: 032.552
  • 24”…………………………………………………. Part Number: 032.553
  • 30”…………………………………………………. Part Number: 032.554
  • 36”…………………………………………………. Part Number: 032.555
  • 48”…………………………………………………. Part Number: 032.556
  • 60”…………………………………………………. Part Number: 032.557
  • 72”…………………………………………………. Part Number: 032.558

Zone Controller Screw-On Cordset (NEMA 4X Zone to Zone Communication for Wash Down Application)
Available for the following zone lengths:

  • 12”…………………………………………………. Part Number: 032.5515
  • 18”…………………………………………………. Part Number: 032.5525
  • 24”…………………………………………………. Part Number: 032.5535
  • 30”…………………………………………………. Part Number: 032.5545
  • 36”…………………………………………………. Part Number: 032.5555
  • 48”…………………………………………………. Part Number: 032.5565
  • 60”…………………………………………………. Part Number: 032.5575
  • 72”…………………………………………………. Part Number: 032.5585

Infeed Zone Terminator
Terminates zone to zone communication at infeed zone.
Part Number: 032.550

Mounting Base
Use to mount any Zone Controller.
Part Number: 032.517

 

Hytrol EZ-Logic IOPIOP QUICK REFERENCE:

Provides 27VDC, 100 watt power for EZLogic“ accumulation system. Requires 120 VAC or 230 VAC single phase input. Operates up to 50 zones (25 zones each side of IOP).– contains slots for 4 input/output boards. Requires enhanced zone controllers to communicate with input/output boards.
Part Number: 032.582

IOP “T” Cable
Required to deliver power and IOP communication from IOP to zone controllers. Max. of 25 zones per each branch of T. Standard Push-On
Part Number: 032.559

I/O Board
Plugs into slot in IOP to provide two input/output connections. Requires enhanced controller to receive signal.
Part Number: 032.583

 

EZLogic Push Button ProgrammerCONFIGURATION and DIAGNOSTIC COMPONENTS QUICK REFERENCE:

Push Button Programmer
Plugs into auxiliary port of any controller to configure certain features of controller. Required for customization of factory default settings.
Part Number: 032.535

Programming Kit for PC and PC Adaptor
Used to connect PC USB port to auxiliary port of any controller. Includes GenesisTM configuration software. Used to configure all features of controller. Required for customization of factory default settings.
Part Number: K-01554

 

EZLogic Diffuse Wake-up EyeAUXILIARY COMPONENTS QUICK REFERENCE:

Auxiliary I/O Module
Plugs into auxiliary port of any controller – used to provide photo eye output or to accept a voltage type input.
Part Number: 032.532

Auxiliary Input Cable
Attaches to any zone controller. Used for zone stop input, wakeup eye input, or slug input. Available in 3 and 10 ft. lengths.

  • 3 ft. ……………………………………………….. Part Number: 032.563
  • 10 ft…………………………………………………Part Number: 032.564

Zone Actuation Module “ZAM” (Alternate Drive)
Provides NPN, PNP, or dry contact output from zone controller.
Part Number: 032.531

Retro-Reflective Wake-up Eye
Plugs into auxiliary port of any controller to send wake-up signal.
Part Number: 032.591

Diffuse Wake-up Eye
Plugs into auxiliary port of any controller to send wake-up signal.
Part Number: 032.592

Retro-Reflectors
2.18” Dia……………………………………………… Part Number: 032.218
3” Dia. ……………………………………………….. Part Number: 033.2132

Connector Covers
Upstream Connector Cover …………………….. Part Number: 032.010

Downstream Connector Cover …………………. Part Number: 032.011

 

Power SplitterCABLE COMPONENTS QUICK REFERENCE:

Power Isolation Cable
Required to isolate DC power when joining conveyors w/ separate IOPs utilizing no more than one set of I/O boards.
Standard Push-On     Part Number: 032.562
NEMA 4X Screw-On  Part Number 032.5625

IOP Isolation Cable
Required to isolate DC power and input/output signals when joining two conveyors with separate IOPs, both utilizing I/O boards.
Standard Push-On      Part Number: 032.570
NEMA 4X Screw-On   Part Number: 032.5705

Extension Cable (Zone to Zone Communication)
Available in 3 and 10 ft. lengths. Used to extend zone controller cable when necessary.
Standard Push-On 3 ft.      Part Number: 032.560
Standard Push-On 10 ft.    Part Number: 032.561
NEMA 4X Screw-On 3 ft.   Part Number: 032.5605
NEMA 4X Screw-On 10 ft. Part Number: 032.5615

Nano Extension Cable
Used to extend auxiliary devices or remote transducer cable. Available in the following lengths:

  • 1 ft      Part Number: 032.565
  • 2 ft.     Part Number: 032.566
  • 3 ft.     Part Number: 032.567
  • 6 ft.     Part Number: 032.568

Power Splitter
Used to connect two conveyors located side by side to one IOP. Requires 2 power supply T cables. Maximum total of 50 zones.
Part Number: 032.569

EZLogic Diffuse Type Zone ControllerSPECIAL USE COMPONENTS QUICK REFERENCE:

Diffuse Type Zone Controller
Zone controller including mounting base and unitized diffuse transducer with adjustable sensitivity (through programming).
24 in. cable.    Part Number: 032.503

Remote Retro-Reflective Transducer
Attaches to any remote zone controller and allows transducer to be mounted separate from controller.
Part Number: 032.511

Remote Diffuse Transducer
Attaches to any remote zone controller and allows transducer to be mounted separate from controller.
Part Number: 032.512

Remote Retro-Reflective Transducer (Dual with T Cable)
For use in dual head applications. Attaches to any remote zone controller and allows addition of second remote transducer.
Part Number: 032.514

Remote Diffuse Transducer (Dual with T Cable)
For use in dual head applications. Attaches to any remote zone controller and allows addition of second remote transducer.
Part Number: 032.515

Remote Diffuse Transducer (Narrow Beam, Dual with T Cable)
For use in dual head applications. Has narrow beam for use with close roller centers. Attaches to any remote zone controller and allows addition of second remote transducer.
Part Number: 032.516

Download Complete Documentation:
Download  EZ-Logic Components
Download EZ-Logic Component Manual  EZ-Logic Component Manual

Previous Page << Hytrol Conveyor System Accessories